- New!
PTAN RCC-F 2020 Compatibility analysis with reference documents
Reference: AFC270
€65.00
unit price Tax excluded
RCC-F 2020 Compatibility analysis with reference documents – WENRA SRL 2014
Type:
PTAN
Edition year:
2020
Free Shipping
Our documents are under copyright
This document compares and analyses the compatibility of the RCC-F 2020 with some reference documents in relation with fire protection. In the present version, the following reference document is analysed:
•WENRA Safety Reference Levels for Existing Reactors - UPDATE IN RELATION TO LESSONS LEARNED FROM TEPCO FUKUSHIMA DAI-ICHI ACCIDENT - 24th September 2014
For each reference document, the compatibility is provided in a dedicated appendix.
To appreciate the compatibility of the RCC-F with the reference documents, four criteria are used:
• A: the principles of the article are fully applied in the RCC-F
• B: the principles of the requirement expressed by the article are applied in the RCC-F but not explicitly expressed
• C: the article is applied in the RCC-F as a recommendation but not as a requirement
• D: the article is not applied in the RCC-F
•WENRA Safety Reference Levels for Existing Reactors - UPDATE IN RELATION TO LESSONS LEARNED FROM TEPCO FUKUSHIMA DAI-ICHI ACCIDENT - 24th September 2014
For each reference document, the compatibility is provided in a dedicated appendix.
To appreciate the compatibility of the RCC-F with the reference documents, four criteria are used:
• A: the principles of the article are fully applied in the RCC-F
• B: the principles of the requirement expressed by the article are applied in the RCC-F but not explicitly expressed
• C: the article is applied in the RCC-F as a recommendation but not as a requirement
• D: the article is not applied in the RCC-F
-
PTAN RCC-F 2020 Compatibility analysis with reference documents
Collaboration and expertise
Take part in updating the codes
If you would like to modify a code, you can send your proposal to the relevant code subcommittee: download and complete the application form, then send the form to the subcommittee email address.
If you would like to understand the interpretation of a paragraph of the code: download the application form, enter your question and send the form to the email address of the relevant subcommittee.
If you want to benefit the nuclear industry from your feedback as a code user, share your expertise with AFCEN: download and complete the application form, then send it to the email address of the relevant subcommittee.